Understanding the U-value and R-value converter — concept and principle
Insulation performance is quoted in two opposite ways. The R-value (thermal resistance) says how strongly a layer resists heat flow; the U-value (thermal transmittance, called U-factor in the US) says how much heat gets through. On top of that, Europe and Korea use SI units while the US uses imperial units, so "R-13" on an American batt is not R 13 in SI. Enter any one of the four values and this converter shows all of them, so you can compare products, windows and wall specs from different countries.
How it is calculated
The calculator first converts your input to SI R-value (m²·K/W):
- from U (SI): R = 1 ÷ U
- from R (US): R(SI) = R(US) ÷ 5.678263
- from U-factor (US): R(SI) = 1 ÷ (U(US) × 5.678263)
Then it reports U(SI) = 1 ÷ R(SI), R(US) = R(SI) × 5.678263 and U(US) = 1 ÷ R(US).
The principle
Heat flow through a wall works like electric current through a resistor. The heat flux is q = U × ΔT, and resistance is the inverse of transmittance, so U = 1 ÷ R. Layers in series add their resistances, which is why designers sum R-values and then invert the total to get U. The factor 5.678263 links the two unit systems: 1 BTU/(h·ft²·°F) equals about 5.678263 W/(m²·K), because it combines the BTU-to-joule, hour-to-second, square-foot-to-square-metre and °F-to-K conversions.
Worked example
Default inputs: R-value (US) = 13, a common wall batt.
- R(SI) = 13 ÷ 5.678263 = 2.289 m²·K/W (shown 2.28943239).
- U(SI) = 1 ÷ 2.28943 = 0.4368 W/(m²·K).
- R(US) stays R-13, and U-factor (US) = 1 ÷ 13 = 0.0769230769 BTU/(h·ft²·°F).
How to read the result
Higher R and lower U both mean better insulation. Doubling R halves U and therefore halves heat loss through that element, but the benefit of each extra step gets smaller in absolute terms. A single-layer R-value covers only that material; whole-assembly values must also include surface air films, framing, fixings and thermal bridges, which usually make the real U-value worse than the insulation alone suggests. Window U-values normally refer to the whole unit including frame.
Common mistakes
- Comparing a US R-value directly with an SI R-value; they differ by a factor of about 5.68.
- Adding U-values of layers instead of adding R-values and then inverting.
- Treating an insulation product's R as the wall's overall R.
Frequently asked questions
How do I convert R-19 to SI?
19 ÷ 5.678263 ≈ 3.35 m²·K/W.
Is a lower U-value better?
Yes. A lower U-value means less heat passes through each square metre per degree of temperature difference.
How do I get R from insulation thickness?
Divide thickness in metres by thermal conductivity: 0.1 m of a 0.035 W/(m·K) material gives about 2.86 m²·K/W.
Sources: ISO 6946, Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods · NIST Special Publication 811 (2008), Guide for the Use of the SI, Appendix B