Understanding the energy use intensity (EUI) calculator — concept and principle
This calculator works out a building's energy use intensity, its yearly energy use per unit of floor area, from a year of electricity, gas, propane and heating-oil bills. EUI lets you compare buildings of different sizes, track savings over time and benchmark against similar buildings, in the way ENERGY STAR Portfolio Manager does.
How it is calculated
- Each fuel is converted to kBtu: 1 kWh = 3.412, 1 therm = 100, 1 US gallon of propane = 92, 1 gallon of No. 2 oil = 138.
- Site energy = sum of those kBtu.
- Source energy = site energy of each fuel × its US site-to-source ratio: grid electricity 2.80, natural gas 1.05, propane and fuel oil 1.01.
- Site EUI = site energy ÷ floor area (ft²); source EUI likewise. Floor area in m² is converted with 1 ft² = 0.09290304 m².
- Site EUI in kWh/m² = site kBtu ÷ 3.412 ÷ floor area in m².
The principle
Dividing by floor area removes the effect of size, so a large and a small home can be compared on the same footing. Site energy is what your meters record. Source energy adds the losses in producing and delivering that energy: generating and transmitting electricity loses much more than piping gas, so electricity carries a larger ratio. Using source energy makes buildings with different fuel mixes comparable in terms of total energy drawn from primary resources. A full year of bills evens out seasonal swings in heating and cooling.
Worked example
Default inputs: 2,200 ft², 10,500 kWh electricity, 550 therms gas, no propane or oil.
- Electricity = 10,500 × 3.412 = 35,826 kBtu; gas = 550 × 100 = 55,000 kBtu.
- Site energy = 90,826 kBtu; site EUI = 90,826 ÷ 2,200 = 41.3 kBtu/ft².
- In metric: 90,826 ÷ 3.412 = 26,620 kWh ÷ 204.4 m² = 130 kWh/m².
- Source = 35,826 × 2.80 + 55,000 × 1.05 = 158,063 kBtu; source EUI = 71.8 kBtu/ft².
- Electricity share = 35,826 ÷ 90,826 = 39.4%.
| Gross floor area | Site EUI (kBtu/ft² per year) |
|---|---|
| 550 | 165.1 |
| 1,100 | 82.6 |
| 1,650 | 55 |
| 2,200 | 41.3 |
| 2,750 | 33 |
| 3,300 | 27.5 |
| 4,400 | 20.6 |
How to read the result
Lower is better for the same type of building and climate. Compare your EUI with your own past years after upgrades, and with similar buildings in a similar climate. A cold climate, electric heating or a home-based business can all raise EUI without poor efficiency. Commercial benchmarks differ greatly by building type, so compare like with like.
Common mistakes
- Using less than 12 months of bills.
- Using heated floor area for one building and gross floor area for another.
- Comparing site EUI of an all-electric building with source EUI of another.
- Forgetting fuels delivered in bulk, such as oil or propane.
Frequently asked questions
What is a good EUI for a home?
It depends on climate and building type; compare with similar homes in your area and with your own past years.
What is the difference between site and source EUI?
Site counts the energy at your meters; source adds generation and delivery losses.
How do I convert kBtu/ft² to kWh/m²?
Multiply by about 3.155 (1 kBtu = 0.2931 kWh and 1 ft² = 0.0929 m²).
Sources: ENERGY STAR Portfolio Manager Technical Reference: Thermal Energy Conversions (2015) · ENERGY STAR Portfolio Manager Technical Reference: Source Energy (2023)