🔬 Science & engineering

Coaxial Cable Impedance Calculator

Results update as you type.

Your numbers

Understanding the coaxial cable impedance calculator — concept and principle

This calculator finds the characteristic impedance of a coaxial line from its geometry and insulation, along with the velocity factor and the capacitance per metre. It is used to check whether a cable or a home-made coaxial section is 50 Ω or 75 Ω, to design matching sections, and to understand cable datasheets.

Coax cross-section and its impedanceShield 7.25 mm, centre 2.0 mm, dielectric εr 2.25: Z₀ = 138/1.5 × log₁₀(3.625) ≈ 51.46 Ω.Impedance is set by the ratio D ÷ dD = 7.25 mmd = 2.0 mmεr = 2.25D ÷ d = 3.6257.25 ÷ 2.00.5593log₁₀ 3.62592138 ÷ √2.25Z₀ = 92 × 0.5593 ≈ 51.46 Ωvelocity factor 0.667 · 97.19 pF/m
Only the diameter ratio and the dielectric matter: 3.625 and εr 2.25 give about 51.5 Ω.

How it is calculated

D is the inner diameter of the shield, d the outer diameter of the centre conductor (same units, only the ratio matters), and εᵣ the relative permittivity of the insulation: about 1.0 for air and about 2.25 for solid polyethylene.

The principle

A coaxial line is a distributed chain of tiny series inductances and shunt capacitances. Per metre, the inductance is L = (μ₀ / 2π) ln(D/d) and the capacitance is C as above. A wave travelling along the line sees the impedance Z₀ = √(L / C), which depends only on the ratio D/d and on εᵣ, not on length. The wave speed is 1 / √(LC) = c / √εᵣ, which gives the velocity factor. Because Z₀ grows only logarithmically with D/d, large changes in geometry make modest changes in impedance.

Worked example

  1. Ratio: D / d = 7.25 / 2.0 = 3.625; log₁₀(3.625) ≈ 0.5593.
  2. 138 / √2.25 = 138 / 1.5 = 92.
  3. Z₀ = 92 × 0.5593 ≈ 51.46 Ω.
  4. Velocity factor: 1 / 1.5 ≈ 0.667.
  5. Capacitance: 2π × 8.854 × 10⁻¹² × 2.25 / ln(3.625) = 1.2517 × 10⁻¹⁰ / 1.2879 ≈ 97.19 pF/m.
How Impedance (Ω) changes with Centre conductor diameter (mm)How Impedance changes with Centre conduc…204060801001200.511.522.534Example: 51.456337Centre conductor diameter (mm)
Each point is the calculator re-run with only “Centre conductor diameter (mm)” changed; the gold point is the default example. Change the inputs above and this chart follows your numbers.
Centre conductor diameter (mm)Impedance (Ω)
0.5106.8458562
179.1510966
1.562.95070077
251.456337
2.542.54061581
335.25594117
423.7615774

How to read the result

50 Ω is the standard for RF transmitters, test equipment and most antennas; 75 Ω is standard for TV, satellite and video. For an air line, attenuation is lowest near 77 Ω and power handling is highest near 30 Ω; 50 Ω is a practical compromise. With solid polyethylene, 50 Ω needs D/d ≈ 3.49 and 75 Ω needs D/d ≈ 6.5. A velocity factor of 0.66 is typical of solid PE cable; foamed dielectrics reach about 0.8 or more.

Common mistakes

Keep in mind: The formula assumes perfectly round, concentric conductors and a lossless, uniform dielectric. Manufacturing tolerances and frequency-dependent losses mean real cables must be verified against the datasheet or measured.

Frequently asked questions

Can I connect 75 Ω cable to a 50 Ω radio?

It works with a mismatch: |Γ| = 0.2, VSWR 1.5, and about 4% of the power reflected. For receiving this is often acceptable; for high-power transmitting, use the correct cable.

Why does capacitance per metre matter?

It sets loading on audio and data lines and lets you identify cable: solid-PE 50 Ω cable is roughly 100 pF/m, 75 Ω cable roughly 67 pF/m.

Sources: Pozar, Microwave Engineering, coaxial line section · The ARRL Handbook for Radio Communications, transmission lines chapter

Checked 8 Nov 2026. Standard textbook formulas in SI units, computed in your browser. For learning and estimates — real designs must follow your local codes and be checked by a qualified engineer.

🔬 All science & engineering tools →🌍 Calculators by country →