Understanding the disinfection CT calculator — concept and principle
CT is the product of disinfectant concentration (C) and contact time (T). Water treatment plants use it to show that chlorine or another disinfectant has had enough "dose" to inactivate pathogens such as Giardia and viruses before water reaches the first customer. You calculate the CT actually achieved and compare it with the CT required by regulatory tables.
How it is calculated
- CT = C × T₁₀, in mg·min/L.
- C is the residual disinfectant concentration (mg/L) measured at the outlet of the contact basin, not the dose added.
- T₁₀ is the time in minutes within which only 10% of the water has passed through the basin, usually found by a tracer test or estimated as the theoretical detention time (volume ÷ peak flow) multiplied by a baffling factor.
The principle
Disinfection follows, to a first approximation, the Chick–Watson law: the logarithm of the surviving fraction of microorganisms falls in proportion to concentration times time. Doubling the residual or the contact time gives roughly the same kill. Using T₁₀ instead of average time is deliberately conservative: real basins short-circuit, and T₁₀ ensures at least 90% of the water receives the calculated CT. Required CT depends on the organism, the disinfectant, temperature (cold water needs more) and, for free chlorine, pH (higher pH needs more).
Worked example
- Inputs: residual free chlorine C = 1 mg/L, T₁₀ = 30 min.
- CT = 1 × 30 = 30 mg·min/L.
- If a regulatory table required, for example, 60 mg·min/L for your conditions, the ratio of achieved to required CT would be 30 ÷ 60 = 0.5, meaning the target is not met.
| Residual chlorine (mg/L) | CT (mg·min/L) |
|---|---|
| 0.25 | 7.5 |
| 0.5 | 15 |
| 0.75 | 22.5 |
| 1 | 30 |
| 1.25 | 37.5 |
| 1.5 | 45 |
| 2 | 60 |
How to read the result
CT means nothing alone; compare it with the required CT for your pathogen, log-inactivation target, disinfectant, pH and temperature. A ratio of achieved to required CT of 1.0 or more meets the target. Viruses are generally inactivated by free chlorine at much lower CT than Giardia, while Cryptosporidium is highly resistant to chlorine and is normally controlled by filtration, UV or ozone. Chloramines need far higher CT than free chlorine for the same effect.
Common mistakes
- Using the chlorine dose instead of the residual remaining at the basin outlet.
- Using the average detention time instead of T₁₀, which overstates CT.
- Calculating with average flow instead of peak hourly flow.
Frequently asked questions
What is a baffling factor?
It is the ratio T₁₀ ÷ theoretical detention time. US EPA guidance gives typical values from 0.1 for an unbaffled tank to 1.0 for pipe (plug) flow; a tracer test gives the real value.
Why does pH matter for chlorine?
Free chlorine exists as hypochlorous acid (HOCl) and hypochlorite (OCl⁻). HOCl is the stronger disinfectant and dominates below about pH 7.5, so disinfection is more effective at lower pH.