Emission O₂ Reference Correction Calculator

Results update as you type.

Your numbers

Understanding the emission O₂ reference correction calculator — concept and principle

Stack emission limits for pollutants such as NOx, CO, SO₂ and dust are usually expressed at a fixed reference oxygen content. This calculator converts a measured concentration to that reference O₂ level, so that a boiler, engine or incinerator cannot appear cleaner simply by diluting its flue gas with extra air.

Oxygen reference correctionAt 9% O₂ only 11.9 of 20.9 points of oxygen were used; scaling to 6% reference (14.9 used) turns 150 into 187.8.Extra air dilutes the flue gasMeasured: 9% O₂ left in the gasO₂ used 11.99%Reference: 6% O₂O₂ used 14.96%020.9% = air150 × 14.9 ÷ 11.9 = 150 × 1.252Corrected ≈ 187.8same unit as the 150 measured
Correcting to a lower reference O₂ removes the dilution, so the number goes up.

How it is calculated

The principle

Excess combustion air does not change how much pollutant is produced, but it adds volume and so lowers the concentration. The term 20.9 − O₂ measures how much oxygen has been consumed by combustion: in undiluted gas with 0% O₂ it is 20.9, and in pure air it is 0. The ratio (20.9 − O₂ref) ÷ (20.9 − O₂meas) is therefore the ratio of flue-gas volumes at the two dilution levels. Multiplying by it rescales the concentration to what it would be if the gas contained exactly the reference amount of oxygen, putting all plants on the same footing.

Worked example

  1. Inputs: measured concentration 150, measured O₂ = 9%, reference O₂ = 6%.
  2. Numerator: 20.9 − 6 = 14.9.
  3. Denominator: 20.9 − 9 = 11.9.
  4. C_ref = 150 × 14.9 ÷ 11.9 = 150 × 1.2521 = 187.8, in the same unit as the measurement.
How Corrected concentration changes with Measured O₂ (%)How Corrected concentration changes with…02004006008002.254.56.75911.213.518Example: 187.8151261Measured O₂ (%)
Each point is the calculator re-run with only “Measured O₂ (%)” changed; the gold point is the default example. Change the inputs above and this chart follows your numbers.
Measured O₂ (%)Corrected concentration
2.25119.8391421
4.5136.2804878
6.75157.95053
9187.8151261
11.2231.6062176
13.5302.027027
18770.6896552

How to read the result

When the measured O₂ is higher than the reference, the corrected value is higher than the measurement, as in the example; when it is lower, the correction reduces the value. Compare only the corrected figure with the limit. Reference levels differ by plant type; in EU rules, for example, 6% is used for solid-fuel combustion plants, 3% for liquid and gaseous fuels, 15% for gas turbines and 11% for waste incineration. Check your own permit for the exact value.

Common mistakes

Keep in mind: The formula is a standard dilution correction, not a substitute for the measurement and calculation methods prescribed in your permit or national emission testing standard. Compliance decisions should follow those rules and accredited measurement bodies.

Frequently asked questions

Why does my plant look worse after correction?

Because it runs with more excess air than the reference level. The correction removes the dilution benefit, which is exactly its purpose.

Should I use 20.9 or 21?

Use the value written in your regulation. The difference is small, but legal reports must follow the official formula.

Sources: Directive 2010/75/EU on industrial emissions, Annexes V and VI (reference oxygen conditions) · EN 15259:2007, Air quality — Measurement of stationary source emissions

Checked 8 Nov 2026. Standard textbook formulas in SI units, computed in your browser. For learning and estimates — real designs must follow your local codes and be checked by a qualified engineer.