Moment Magnitude (Mw) Calculator

Results update as you type.

Your numbers

Understanding the moment magnitude (Mw) calculator — concept and principle

Moment magnitude (Mw) measures the size of an earthquake from the physics of the fault itself: how stiff the rock is, how large an area ruptured and how far the two sides slipped. It is the scale seismologists use for moderate and large earthquakes.

Moment magnitude from fault size and slip30 GPa rock, a 1,000 km² rupture and 2 m slip give M0 = 6 × 10¹⁹ N·m and Mw ≈ 7.12.Seismic moment = stiffness × area × slipA1,000 km²D = 2 mslipμ = 30 GPa (rock stiffness)3×10¹⁰ Pa × 10⁹ m² × 2 m = 6×10¹⁹ N·mMw = ⅔(19.78 − 9.1) ≈ 7.1log₁₀ M₀ = 19.78
A 1,000 km² fault slipping 2 m stores a moment of 6 × 10¹⁹ N·m — Mw 7.1.

How it is calculated

M₀ = μ × A × D

Mw = (2/3) × (log₁₀M₀ − 9.1)

The principle

A fault slip is equivalent to a pair of opposing force couples acting on the fault. Their strength, the seismic moment, equals rigidity times area times slip, a quantity that can also be measured from long-period seismic waves, so it is grounded in mechanics rather than in the response of one instrument. Hanks and Kanamori defined Mw in 1979 so that it matches the older magnitude scales over the range where they work, giving the factor 2/3 and the constant 9.1 for M₀ in N·m (equivalent to 16.1 when M₀ is in dyne-cm). Because the moment keeps growing with fault size, Mw does not saturate the way the local and surface-wave scales do above about magnitude 8.

Worked example

  1. Inputs: μ = 30 GPa, A = 1,000 km², D = 2 m.
  2. Convert units: μ = 3 × 10¹⁰ Pa, A = 1 × 10⁹ m².
  3. M₀ = 3 × 10¹⁰ × 1 × 10⁹ × 2 = 6 × 10¹⁹ N·m.
  4. log₁₀(6 × 10¹⁹) = 19.77815.
  5. Mw = (2/3) × (19.77815 − 9.1) = (2/3) × 10.67815 = 7.1187675, about Mw 7.1.
How Seismic moment (N·m) changes with Shear modulus (GPa)How Seismic moment changes with Shear mo…02.5e+195e+197.5e+191e+201.25e+207.51522.53037.54560Example: 6e+19Shear modulus (GPa)
Each point is the calculator re-run with only “Shear modulus (GPa)” changed; the gold point is the default example. Change the inputs above and this chart follows your numbers.
Shear modulus (GPa)Seismic moment (N·m)
7.51.5e+19
153e+19
22.54.5e+19
306e+19
37.57.5e+19
459e+19
601.2e+20

How to read the result

Each unit of Mw corresponds to about 31.6 times more seismic moment, and 0.2 units is roughly a doubling. A fault about 50 km long and 20 km wide slipping 2 m, as in the example, gives a large earthquake near Mw 7.

Common mistakes

Keep in mind: Real ruptures have uneven slip, varying rigidity with depth and uncertain area. Treat the result as a scenario estimate, not a forecast of an earthquake on a particular fault.

Frequently asked questions

Why is Mw preferred over the Richter scale?

The Richter (local) scale saturates for big earthquakes because short-period waves stop growing, while seismic moment keeps increasing with fault size.

How much slip did the largest earthquakes have?

Great subduction earthquakes have produced average slip of several metres to over ten metres across areas of tens of thousands of square kilometres.

Does a larger shear modulus mean a stronger earthquake?

For the same area and slip, yes, because moment is proportional to μ. In reality stiffer rock also tends to slip less.

Sources: T. C. Hanks and H. Kanamori (1979), "A moment magnitude scale", Journal of Geophysical Research 84(B5), 2348–2350 · H. Kanamori (1977), "The energy release in great earthquakes", Journal of Geophysical Research 82(20), 2981–2987

Checked 8 Nov 2026. Standard textbook formulas in SI units, computed in your browser. For learning and estimates — real designs must follow your local codes and be checked by a qualified engineer.