Venturi Meter Flow Calculator

Results update as you type.

Your numbers

Understanding the Venturi meter flow calculator — concept and principle

A Venturi meter measures flow in a closed pipe by narrowing it smoothly to a throat and measuring the pressure difference between the full pipe and the throat. From the two diameters, the measured pressure difference, the fluid density and a discharge coefficient, the calculator returns the volumetric flow in L/s and the mean velocity in the throat. It is used in water supply, process plants and laboratories because the device has no moving parts and recovers most of its pressure loss.

Venturi meter with two pressure tubesWater speeds up from 1.13 m/s in the 100 mm pipe to 4.53 m/s in the 50 mm throat. The tube above the throat stands 10 kPa (about 1.02 m) lower, which gives a flow of 8.89 L/s.Fast water in the throat has less pressureΔp = 10 kPa≈ 1.02 m of waterD 100 mm1.13 m/sthroat 50 mm4.53 m/sFlow Q = 8.89 L/sfrom Δp, both areas and Cd 0.98
The pressure gap between pipe and throat tells how much water is flowing: 8.89 L/s.

How it is calculated

The principle

Between the inlet and the throat the flow speeds up, as the continuity equation requires (A₁v₁ = A₂v₂), and by Bernoulli's equation the pressure must drop. Combining the two gives an ideal throat velocity of √(2Δp ÷ (ρ(1 − β⁴))). The term 1 − β⁴ corrects for the fact that the fluid was already moving in the pipe. Real flow has friction and a non-uniform velocity profile, so the ideal value is multiplied by the discharge coefficient C_d. For well-made classical Venturi tubes C_d is close to 1 (about 0.98–0.995 in ISO 5167-4, depending on construction).

Worked example

  1. Inputs: D = 100 mm, d = 50 mm, Δp = 10 kPa, ρ = 1000 kg/m³, C_d = 0.98.
  2. A₁ = 0.0078540 m², A₂ = 0.0019635 m², so (A₂/A₁)² = 0.25² = 0.0625.
  3. Ideal throat velocity: √(2 × 10,000 ÷ (1000 × 0.9375)) = √21.333 = 4.6188 m/s.
  4. Actual throat velocity: 0.98 × 4.6188 = 4.526 m/s (shown as 4.52642611).
  5. Q = 0.0019635 × 4.5264 = 0.0088876 m³/s = 8.888 L/s (shown as 8.887616885).
How Flow (L/s) changes with Discharge coefficientHow Flow changes with Discharge coeffici…051015200.2450.490.7350.981.231.471.96Example: 8.887616885Discharge coefficient
Each point is the calculator re-run with only “Discharge coefficient” changed; the gold point is the default example. Change the inputs above and this chart follows your numbers.
Discharge coefficientFlow (L/s)
0.2452.221904221
0.494.443808442
0.7356.665712664
0.988.887616885
1.2311.10952111
1.4713.33142533
1.9617.77523377

How to read the result

Flow is proportional to the square root of Δp, so doubling the flow requires four times the pressure difference. This limits the useful range of one meter (turndown): at a tenth of full flow the pressure signal is only a hundredth as large and becomes hard to read accurately. Choose the throat so that normal flow gives a clearly measurable Δp.

Common mistakes

Keep in mind: Results assume a full pipe, steady incompressible flow and enough straight pipe upstream. For custody transfer or design work, follow ISO 5167 or the applicable standard and use a calibrated C_d.

Frequently asked questions

Why is a Venturi more efficient than an orifice plate?

The gradual diverging cone lets the fluid slow down smoothly, so most of the pressure is recovered; an orifice loses much more energy in turbulence.

What β ratio is typical?

ISO 5167-4 covers classical Venturi tubes with β between 0.3 and 0.75.

Can I find Δp from a known flow?

Rearrange: Δp = ρ(1 − β⁴) ÷ 2 × (Q ÷ (C_d A₂))².

Sources: ISO 5167-4, Measurement of fluid flow by means of pressure differential devices — Part 4: Venturi tubes · F. M. White, Fluid Mechanics, McGraw-Hill (flow meters)

Checked 8 Nov 2026. Standard textbook formulas in SI units, computed in your browser. For learning and estimates — real designs must follow your local codes and be checked by a qualified engineer.